Part Number Hot Search : 
CP012 1A28A 2405SH3 MC6804J1 RBV1006 208LT 2405A MAX3394
Product Description
Full Text Search
 

To Download LOK4001-2RLD Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 LOS, LOR, LOK 4000 15, 30 and 50 Watt AC-DC Converters
Universal input range 85...264 V AC Single output 5.1, 12, 24 or 48 V DC 3 kV AC I/O electric strength test voltage
LGA
* Compact design * Battery charger versions * Operating ambient temperature range -10...50C with convection cooling
Selection chart
Output Input voltage Rated power Uo nom Io nom Ui TA = 50C [V DC] [A] [V AC] Po tot [W] 5.1 5.2 85...264 26 12 1.25 85...264 15 12 2.5 85...264 30 12 4 85...264 48 12...12.81...15 3.6 85...264 49 24 0.65 85...264 15 24 1.25 85...264 30 24 2 85...264 48 24...25.71...30 1.8 85...264 49 48 1 85...264 48 48...51.41...60 0.9 85...264 49 1 Setting voltage U o set for battery charger with R-input open circuit. 2 For minimum order quantity and lead time contact Power-One. Type Options2
LOK 4001-2RLD LOS 4301-2 LOR 4301-2 LOK 4301-2R LOK 4140-2RLD LOS 4601-2 LOR 4601-2 LOK 4601-2R LOK 4240-2RLD LOK 4801-2R LOK 4740-2RLD
F, F1, K
Input
Input voltage Input frequency Inrush current world wide mains, single phase battery powered limited by NTC 16 85...264 V AC 88...372 V DC 47...63 Hz
Output
Efficiency Output voltage setting accuracy Output voltage ripple & noise Line load regulation Minimum load Current limitation Current limitation (L) Operation in series Operation in parallel Hold-up time
Ui nom, Io nom up to 86% Ui nom, 50% of Io nom 1.5% Uo nom Ui nom, Io nom <1% Uo nom Ui min...Ui max, Io = 10...100% of Io nom 1% not required 12/24/48 V types, hiccup mode short-time overload capability 5V types and battery chargers, rect. U/I charact. max. 130% Io nom add reverse polarity diodes to the outputs with battery charger versions possible 115/230 V 14/90 ms
242
www.power-one.com
Edition 5/07.2001
DIN Rail Mountable
Protection
Input fuse Input transient protection Output
LOS, LOR, LOK 4000 Series
not user accessible voltage depending resistor (VDR) no-load, overload and short circuit proof 1.6 A, slow blow
Control
Status indication LED output O.K. Output voltage adjustment R input - recitfier version Output undervoltage monitoring D battery charger 90...110% Uo nom typ. 80% Uoset
Safety
Approvals Electric strength test voltage EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed input/protective earth input/output output/protective earth in progress 1.5 kV AC 3 kV AC 1 kV AC 2 IP 20
Pollution degree Degree of protection
EMC
Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level 2 (8 kV) IEC/EN 61000-4-3, level 2 (3 V/m) IEC/EN 61000-4-4, level 3 (2 kV) IEC/EN 61000-4-5, level 3, line to prot. earth (2 kV) IEC/EN 61000-4-5, level 2, line to line (1 kV) IEC/EN 61000-4-6, level 2 (3 V) CISPR 22/EN 55022, conducted criterion B criterion B criterion B criterion B criterion B criterion A class B
Environmental
Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump MTBF
Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40C IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-27 IEC/EN 60068-2-29 MIL-HDBK-217F, 6B, 40
-10...50C -10...80C -40...85C 21 days 0.15 mm/2 gn 11 ms/15 gn 11 ms/10 gn 1'600'000 h
Options
Built-in second fuse in the neutral No fuse fitted (operation from DC voltage) System connectors with screw terminals F F1 K
www.power-one.com
Edition 5/07.2001
243
LOS, LOR, LOK 4000 15, 30 and 50 Watt AC-DC Converters
Mechanical data
Tolerances 0.3 mm (0.012") unless otherwise indicated.
S90042
European Projection
1.8 (4.25") 113.6 (4.47")
244
www.power-one.com
Edition 5/07.2001
90 (3.54")
38 (1.5")
DIN Rail Mountable
Terminal allocation
Terminal 1 2 3 4 5 6 7 8 Determination Input Protective earth Input Output (positive)/D Output (positive) Output (negative) Output (negative) n.c./R input LOS, LOR L N Vo+ Vo+ Vo- Vo- n.c. LOK L
LOS, LOR, LOK 4000 Series
N Vo+/D Vo+ Vo- Vo- R
Accessories
Protective covers over input and output terminals
www.power-one.com
Edition 5/07.2001
245


▲Up To Search▲   

 
Price & Availability of LOK4001-2RLD

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X